THERMAL Home | Components | Ports | Classes | Functions | Enumeratives | Global Variables

THERMAL.Peltier



COMPONENT Peltier

ICON:


DESCRIPTION:
Thermoelectric heat pump model

CONSTRUCTION PARAMETERS:
NAME  TYPE  DEFAULT  DESCRIPTION  UNITS  
INTEGER  Dimension of thermal port (-) 

PORTS:
NAME  TYPE  PARAMETERS  DIRECTION  CARDINALITY  DESCRIPTION  
e_n PORTS_LIB.elec  IN   Electrical outlet port for the p-type semiconductor 
e_p PORTS_LIB.elec  IN   Electrical inlet port for the n-type semiconductor 
tp_in PORTS_LIB.thermal  (n = n)  IN   Thermal inlet port 
tp_out PORTS_LIB.thermal  (n = n)  OUT   Thermal outlet port 

DATA:
NAME  TYPE  DEFAULT  RANGE  DESCRIPTION  UNITS  
REAL  0.04  Area length of the TE elements 
NTE INTEGER   Number of TE elements 
a_coef[3] REAL  { 2.2224e-005,9.306e-007,...  Temperature coefficients of seebeck effect (V/K, V/K^2, V/K^3) V/K, V/K^2, V/K^3 
k_coef[3] REAL  { 6.2605,-0.02777,4.131e-...  Temperature coefficients of thermal conductivity (W/m*K, W/m*K^2, W/m*K^3) W/m*K, W/m*K^2, W/m*K^3 
r_coef[3] REAL  { 5.112e-007,1.634e-008,6...  Temperature coefficients of resistivity (Ohm*m, Ohm*m/K, Ohm*m/K^2) Ohm*m, Ohm*m/K, Ohm*m/K^2 

DECLS:
NAME  TYPE  INITIAL  RANGE  DESCRIPTION  UNITS  
COP REAL    Coefficient of performance 
COPopt REAL    Optimum coefficient of performance 
DT REAL    Temperature jump 
DTmax REAL    Maximum temperature jump 
REAL    Current 
Imax REAL    Maximum Current 
Iopt REAL    Optimum Current 
Pel REAL    Electrical power 
Tk_ave REAL    Average temperature 
Tk_in REAL    Inlet temperature 
Tk_out REAL    Outlet temperature 
REAL    Voltage 
REAL    Figure of Merit 1/K 
REAL    Seebeck coefficient V/K 
REAL    Thermal conductivity W/(m�K) 
qin REAL    Inlet heat flux 
qout REAL    Outlet heat flux 
REAL    Resistivity Ohm�m 
FORMULATION:






Document generated automatically with EcosimPro Version: 5.4.14 Date: 2015:02:02 Time: 10:24:21